The SCALEXIO FIU concept with an example selection of HighFlex I/O boards.
Fault simulation lets you insert faults, such as broken wires and short circuits, on the electrical level. For fault simulation, dSPACE provides an integrated solution on the SCALEXIO HighFlex I/O boards and the MultiCompact I/O unit. Additionally, customized rack systems can be equipped with special fault simulation solutions to provide higher currents or more fail rails.
Feature | SCALEXIO FIU | SCALEXIO Customized Rack Systems Variant 1 | SCALEXIO Customized Rack Systems Variant 2 | SCALEXIO Customized Rack Systems High-Current |
---|---|---|---|---|
General | Integrated with SCALEXIO MultiCompact I/O units and HighFlex boards |
|
|
|
I/O boards with integrated FIU |
|
DS291 | DS282 | DS5355/DS5390 |
Number of cards per simulator | Via the I/O boards | Configurable | Configurable | Configurable |
Number of channels per card | Depends on I/O board | 10 | 10 | Up to 9 |
Switch type |
|
Relay | Relay | Relay |
Max. continuous current | Up to 80 A (depends on I/O board) | 8 A | 8 A | 50 A |
Possible fault types | SCALEXIO FIU | SCALEXIO Customized Rack Systems Variant 1 | SCALEXIO Customized Rack Systems Variant 2 | SCALEXIO Customized Rack Systems High-Current |
---|---|---|---|---|
Broken wire | Included | Included | Included | Included |
Short circuit to ground | Up to 10 channels | Included | Included | Included |
Short circuit to battery voltage | Up to 10 channels | Included | Included | Included |
Short circuit to another ECU pin via common failrail | Up to 10 channels | Included | Included | Included |
Broken wire with additional hardware (Rsim, Meas or Source) in series | Not available | Not available | Included | Not available |
Short circuit to another ECU pin via additional hardware (Rsim, Meas or Source) | Not available | Not available | Included | Not available |
Short circuit to 5 reference points (potential 0 ... 4) directly or via additional hardware (Rsim, Meas or Source) | Not available | Not available | Included | Not available |
The SCALEXIO Failure Insertion Unit (FIU) consists of several components:
The SCALEXIO HighFlex and MultiCompact boards include a fault simulation (FS) function. You need an additional FS license to activate the fault simulation. The FS license will be checked at the host PC. Each license can be used for one SCALEXIO system. The licenses are scaled for fault simulation with different numbers of I/O channels capable of fault simulations. The fault simulation is configured in ConfigurationDesk, so you need the appropriate SCALEXIO Failure Simulation license for the number of I/O functions that are mapped to channels with an FRU that you use in your real-time application. The FS license is needed only for running the simulation, not for configuring the I/O channels with ConfigurationDesk.
The diagnostic functions of ECUs have to detect each fault within a specified time. To help test an ECU’s diagnostic functions, SCALEXIO provides FIU state tracing. This enables you to measure or plot FIU states and therefore to monitor the time from a change in FIU state to any other event, such as the detection of the fault.
SCALEXIO supports the simultaneous insertion of multiple faults during simulation to allow fault classes such as broken wire, short circuit to ground or UBAT, or short between channels. This function can be enabled in ConfigurationDesk for channels without current enhancement.
For the customized system, additional types of fault simulation are available in addition to SCALEXIO Fault Simulation. This enables you to tailor the system to your project-specific requirements. The fault simulation for customized sytems can be remotely controlled with the ControlDesk Failure Simulation Module or, optionally, with AutomationDesk.
Variant 1 for fault simulation on SCALEXIO supports fault simulation on all ECU input and output pins. All digital and analog I/O boards from dSPACE can be used for fault simulation. The relay boards (DS291) for fault simulation can be used on their own for fault simulation on sensor signals (ECU inputs) or in conjunction with load boards (DS281) on actuator signals (ECU outputs). Fault relays are controlled via a serial RS232.
The second fault simulation variant uses a central relay switching matrix (DS293) for fault simulation on ECU inputs and outputs. Five different system potentials (for example, Terminal 30, Terminal 31, Terminal 15) can be switched on three different rails via load modules (DS282). Further devices that can be connected, including various measurement devices (Meas0-4), an electronic source (Source), and Rsim modules for transition impedance. Fault simulation is controlled via a CAN interface.
The high-current fault simulation unit on SCALEXIO supports fault simulation on ECU inputs and outputs. One FIU controller card (DS5355) supports up to 19 signal channels on two high-current FIU relay trays (DS5390). Due to its modularity, the FIU controller card can be expanded to increase the number of channels. These relay trays allow for faults with currents up to 50 A and voltages of up to 300 V. The FIU is controlled from ControlDesk via a serial RS232 or CAN.