Many development tasks in the field of aerospace engineering demand the applied hardware to be highly insensitive to height, temperature, and mechanical influences (vibration, impact), and to sources of electromagnetic disturbances. To confirm that dSPACE MicroAutoBox II is qualified for such scenarios, it was put through various tests in accordance with DO-160. The following table shows an overview of the tests in which MicroAutoBox II executed its running programs completely error-free.
Electromagnetic compatibility (EMC) | EN 61326-1 Table 2 | Immunity standard for industrial environment |
CISPR 11, EN 55011 Group 1, Class A | Emission standard for industrial environments | |
RTCA/DO160G: Dec. 2010: Section 21.4 | Conducted RF Emissions, Category: B, L, M&H | |
RTCA/DO160G: Dec. 2010: Section 21.5 | Radiated RF Emissions, Category: M | |
Vibration | ISO 16750-3:2007 / 4.1.2.4 Test IV | Test conditions: Broad band noise, 4h per axis, RMS-acceleration 27,8 m/s2 |
DO-160F.8 / B1 Test Conditions | Test conditions: Broad band noise, 2h per axis, based on DO160F Section 8, Category B1 |
|
EN 60068-2-6 | Test conditions: Swept sine, 1 octave per minute, 3-axis test 5 ... 2000 Hz, up to 5 g, 2 sweeps per axis / Operating |
|
Shock | ISO 16750-3:2007 / 4.1.2.4 Test IV | Linear shock (1/2 sine pulse), 6-axis 500 m/s2, 6 ms, 10 pulses per axis / Operating |
RTCA / DO 160F Section 7 Test 7.2 Category A, Test type R | Operational shocks test (standard): Saw tooth wave, 6 axis 200 m/s2, 11 ms, 10 pulses per axis / Operating |
|
RTCA / DO 160F Section 7 Test 7.2 Category D, Test type R | Operational shocks test (low frequency): Saw tooth wave, 6 axis 200 m/s2, 20 ms, 10 pulses per axis / Operating |
|
Altitude Test | DO160G Section4: Test 4.6.1 Altitude Test | 50.000 feet (15.240m) |
Overpressure & Decompression | DO-160G Section 4: Test 4.6.2 Overpressure Test | Pressure: Maximum: 170kPA, Minimum 11,6kPA |
Test 4.6.3 Decompression Test | ||
Temperature Variation & Ground survival & Short-time operation | DO-160F Section 4&5: | Test Requirement: Acc. to DO160F Section 4 & 5 Category B2 Tmin = -55°C; Tmax =+85°C; 2 cycle (ap.36h) |
Test 4.5.1 Ground Survival Low Temperature Test and Short-Time Operating Low Temperature Test | ||
Test 4.5.2 Operating Low Temperature Test | ||
Test 4.5.3 Ground Survival High Temperature Test and Short-Time Operating High Temperature Test | ||
Test 4.5.4 Operating High Temperature Test | ||
Test 5.3.1 Temperature variation test |