FAQ 791: Processing Unit Not Accessible
Question
What to do when the SCALEXIO Processing Unit is not accessible?
Solution
Follow the steps below to identify and resolve the issue.
1. Quick Check – Is the Processing Unit reachable via the web interface?
Open a web browser and enter the IP address of the Processing Unit (PU).
If the PU is accessible:
- Open the SUPPORT page
- Generate a Limited Report (*.tgz)
- Contact dSPACE Support and request an upload link (see step 8)
- Upload the report for analysis
This is usually the fastest way to resolve the issue.
If the PU is not accessible:
Continue with the steps below. They describe which information should be collected when contacting dSPACE Support.
2. Identify Your Hardware
Provide the following information when contacting dSPACE Support:
- PU type
- If unknown: serial number (SN) or label information
The label can be found:
- On the rear side
- On the left side
- Behind the front flap (depending on the PU type)
3. Observe Boot Behavior
Check how the system behaves during startup:
- Record a video of the LEDs (PWR/SYS/APP)
- Include any acoustic signals (beeps) if possible
- Alternatively: Compare the LED behavior with Table 1
This information is helpful for troubleshooting.
4. Connect a Monitor
Sending a video of the boot information displayed on the monitor can help dSPACE Support diagnose the issue.Connect a monitor to the PU and restart the system.
Check for:
- Displayed IP address
- Error messages
- Boot messages
The system has booted successfully if you see:
- An IP address
- The string “DS-86_32” with firmware information
In this case, continue with network troubleshooting (Step 5).
5. Check the Network Connection
- Verify the Ethernet cable connection
- Replace the cable if necessary
- Ensure the cable is connected to the host interface
- Ensure the cable is not connected to the 2nd Ethernet port
- Check for LED activity on the network connector
- Test with a direct (peer-to-peer) connection
- Ensure:
- The host and PU are in the same subnet
- The PU responds to ping
6. Perform Hardware Checks
If the PU does not boot properly (see step 4, Monitor), check the following components:
6.1 Boot Medium (SSD/CompactFlash)
- Identify the boot medium used, see Table 2
- If available:
→ Cross-swap the boot medium with a working system
Additional steps for CompactFlash only:
- dSPACE Support can provide an image file
- Rewriting the card often resolves issues
- If not, the card might be defective
6.2 DS2502 Router Board
- The DS2502 IOCNET Board can cause boot issues
- If available:
→ Test with a replacement board
6.3 RAM
- Remove and reinsert the RAM modules
- Clean the contacts if necessary
- Insert the bar in another slot only for testing
- If multiple modules are installed:
- Test them one by one
- Remove one to check whether the behavior changes
⚠️ Follow ESD precautions
6.4 CMOS Battery
Typical symptom: repeated restarts
Procedure:
- Disconnect the power supply
- Wait at least one minute
- Measure the battery voltage (with the battery still installed) at positive pole against housing ground
- ≥ 2.6 V → OK
- < 2.6 V → Replace battery, see SCALEXIO Processing Unit - dSPACE
6.5 Power Supply/Mainboard
If possible:
- Remove the PU from the HIL system
- Connect it directly to the mains power supply
If:
- No LEDs light up
- The system shows no activity
→ Likely causes:
- Defective power supply
- Defective mainboard
7. Factory Mode
You can force the PU into factory mode:
- Connect a keyboard (USB)
- Press the B key during startup
- Hold until the SYS LED turns red (~30–40 s)
If it does not work (e.g., on an HCP-P02)
- Connect also a monitor (Display Port)
- Watch the screen output
- Press the B key when you see output similar to that shown in Photo 1
Result:
- System should become accessible again (as long as it is not defective)
- A firmware update is required
Note: This does NOT reset the IP nor the configuration
8. Contact dSPACE Support
If the issue persists:
- Contact dSPACE Support
- If necessary, provide:
- PU type or serial number
- LED behavior
- Photos or videos
- Report file (if available)
To send the device in for repair, see Hardware Repairs / RMA
Tables
Table 1: Table of LED states from PU:
| PWR | SYS | APP | Description |
|---|---|---|---|
|
Off |
Off |
Off |
The SCALEXIO system is switched off. |
|
Green |
Any |
Any |
The power supply is OK. |
|
Green |
Off (permanent) |
Off |
If the SCALEXIO system is switched on and the SYS LED is off for longer than 60 s, the SCALEXIO processing hardware is defective. Contact dSPACE Support. |
|
Green |
Off (temporary) |
Off |
The BIOS initialization is running. |
|
Green |
Red (permanent) |
Off |
Error state, contact dSPACE Support. |
|
Green |
Red (temporary) |
Off |
The BIOS initialization is complete. The SCALEXIO RTLib is booting. |
|
Green |
Red/orange flashing |
Red/orange flashing |
The FPGA is loaded. The installed DS2502 IOCNET Link Board is not detected. Error state, contact dSPACE Support. |
|
Green |
Red/orange flashing |
Off |
The installed DS2502 IOCNET Link Board is detected. The BIOS initialization is still running. SCALEXIO RTLib has not yet booted completely. If this state is displayed longer than 60 s, the SCALEXIO system cannot boot due to a general boot problem or a defect. Contact dSPACE Support. |
|
Green |
Green flashing |
Off |
SCALEXIO RTLib has booted. The Ethernet connection to the host PC has not been established (yet). |
|
Green |
Orange/green flashing |
Off |
SCALEXIO RTLib is ready. The Ethernet connection to the host PC has been established. The IP address has not been set (yet). The processing unit is waiting for the DHCP server. |
|
Green |
Green |
Off |
The SCALEXIO system is ready for operation. SCALEXIO RTLib is ready. The Ethernet connection to the host PC has been established. The IP address has been set. No application is loaded. |
|
Green |
Green flashing (three times) |
Green flashing (three times) |
Status message when specifying the network configuration: The network configuration was successful. Shut down and restart the SCALEXIO system to activate the settings. |
|
Green |
Red flashing (three times) |
Red flashing (three times) |
Status message when specifying the network configuration: The SCALEXIO system detected the configuration service, but the configuration was not successful. Ensure that the SCALEXIO system is not accessed by software, such as ConfigurationDesk or ControlDesk, and no real-time application is loaded to the system. |
|
Green |
Green |
Green |
An application is loaded and running. |
|
Green |
Green |
Orange |
An application is loaded. A simulation is running and a connection to the electrical error simulation service is established. |
|
Green |
Green |
Red |
An application loaded is stopped or terminated. |
Table 2: Boot medium
|
PU Variant is Booting From |
SSD |
CompactFlash (CF) card |
|---|---|---|
|
HCP P01 |
|
Yes |
|
HCP P02 |
|
Yes |
|
HCP P03 |
|
Yes |
|
HCP P04 |
Yes |
|
|
HPP P01 |
|
Yes |
|
HPP P02 |
Yes |
|
|
HPP P03 |
Yes |
|
|
ES P01 |
Yes |
|
Tags
| Date | 2026-09-25 |
| 产品 | SCALEXIO Processing Unit |
| 资料信息 | 常见问答 |
| 信息类别 | 故障排除 |