FAQ 786: How to Measure and Record Data in ControlDesk Using Downsampling (Instead of HostService)​

Question

I have a simple Simulink model built and run on a DS1401 target. 
I would like to select a raster for recording in ControlDesk 6.3, but I can only select "HostService" which is the sampling time specified in the model.
Is it possible to set and select a different raster in ControlDesk or at build time?
Specifically, I would like to record a raster that is specified as 1ms, but then thinned out to 10ms, 100ms, and so on.

Solution

As a method for performing measurement and recording at integer multiples of the basic sample time, ControlDesk provides the “Down Sampling function”.

Please follow the procedure below.

Setting up downsampling (measurement thinning):

  1. Open a project in ControlDesk.
  2. Right-Click "Measurement Configuration" > "Acquisition" > "Platform" > "HostService". Then select “Properties”.
  1. Downsampling is displayed in “Properties”. (Default setting=1)
    In the default setting, measurement and recording are performed at the basic sample time.
  1. Enter an integer value in the Downsampling field.
    (If the basic sample time is 1 ms, enter 10 for 10 ms, 100 for 100 ms, etc.)
    *Downsampling settings are also applied during recording.

Tags

Date 2026-11-02
资料信息 常见问答

通过 dSPACE时事通讯服务了解最新信息。

通过 dSPACE 时事通讯服务,我们将随时向您通报当前的使用案例、新解决方案和产品以及培训和活动。在此注册,免费订阅。

Enable form call

At this point, an input form from Click Dimensions is integrated. This enables us to process your newsletter subscription. The form is currently hidden due to your privacy settings for our website.

External input form

By activating the input form, you consent to personal data being transmitted to Click Dimensions within the EU, in the USA, Canada or Australia. More on this in our privacy policy.