FAQ 567: CodeMeter WebAdmin Does Not Open After Changing the Port Settings

Question

Why does CodeMeter WebAdmin fail to open after the NetworkPort setting was modified, and how can I restore access?

Figure 1: Browser error displayed when accessing CodeMeter WebAdmin

Solution

If the NetworkPort value is changed incorrectly, CodeMeter WebAdmin might be inaccessible. The NetworkPort, HTTP port, and HTTPS port must each use different port numbers. By default, these ports are configured as 22350, 22352, and 22353 respectively.

  1. Open Windows Search.
  2. Type “Registry Editor” and launch it.
  3. Navigate to:
    HKEY_LOCAL_MACHINE
    └─ SOFTWARE
       └─ WIBU-SYSTEMS
          └─ CodeMeter
             └─ Server
                └─ CurrentVersion

 

  1. In the CurrentVersion folder, double-click NetworkPort.
     
  1. Enter 22350 in Value Data, select Decimal in Base, then click OK.
  1. After restoring the NetworkPort to 22350, repeat the procedure to restore the HTTP and HTTPS port settings.
  2. To change the HTTP port number, follow the same procedure as for NetworkPort to navigate to the Server folder.
  3. Open CurrentVersion and select HTTP. From the file and folder listing, double-click Port.
  1. Enter 22352 in Value Data, select Decimal in Base, then click OK.
  1. To change the HTTPS port number, follow the same procedure as for NetworkPort to navigate to the Server folder.
  2. Open CurrentVersion and select HTTPS. From the file and folder listing, double-click Port.
  1. Enter 22353 in Value Data, select Decimal in Base, then click OK.
  1. You have now restored the Network, HTTP, and HTTPS ports to their default values.
  2. Open the CodeMeter Control Center and select:
    Process -> Restart CodeMeter Service.
  1. Reopen WebAdmin in the browser.
  2. Verify that WebAdmin loads successfully.
  3. For network-based license setups, verify that the same port settings have been configured on all relevant client systems that communicate with the license server.
  1. For verification, after you restart the CodeMeter Service, open the following URL:
    http://localhost:22352/
  2. The CodeMeter WebAdmin page should open successfully. If this page does not open successfully, repeat the steps above.

Tags

Date 2026-11-06
资料信息 常见问答
信息类别 安装和许可证, 迁移, 故障排除

通过 dSPACE时事通讯服务了解最新信息。

通过 dSPACE 时事通讯服务,我们将随时向您通报当前的使用案例、新解决方案和产品以及培训和活动。在此注册,免费订阅。

Enable form call

At this point, an input form from Click Dimensions is integrated. This enables us to process your newsletter subscription. The form is currently hidden due to your privacy settings for our website.

External input form

By activating the input form, you consent to personal data being transmitted to Click Dimensions within the EU, in the USA, Canada or Australia. More on this in our privacy policy.