FAQ 569: ConfigurationDesk: Configuring the Baud Rate at Run Time
Question
How do you change the baud rate at run time without rebuilding the application?
Solution
Starting with Release 2023-B, the CAN baud rate can be changed at run time without rebuilding or re-downloading the application. By configuring the baud rate source from the model, users can modify CAN communication settings dynamically, reducing development and deployment effort.
Steps to Configure Run-Time Baud Rate Changes
Step 1: Open ConfigurationDesk
-
Launch ConfigurationDesk.
- Navigate to the Signal Chain configuration.
Step 2: Select the CAN Channel
- Locate the assigned CAN channel in the Signal Chain.
- Open the channel's General Properties.
Step 3: Configure the Baud Rate Source
Under the baud rate and sample point configuration settings, two source options are available:
- Function Block
- Baud rate and sample point values are defined through function blocks in the model.
- Model
- Baud rate and sample point values are provided directly by the model and can be modified at run time.
Step 4: Enable Run-Time Configuration
- Select Model as the source for the baud rate and sample point configuration.
- Build and deploy the application once with this configuration.
- After deployment, the baud rate can be adjusted at run time through the model interface without requiring an application rebuild.
Note: This functionality is available from Release 2023-B and later. Ensure that the CAN channel is configured to use Model as the source for baud rate and sample point settings.