FAQ 284: A non-zero voltage is measured on the analog input channel of MABX III if the input is open

Question

On the Analog In channel of MABX III, I am measuring a non-zero voltage at the input pin when the input is open. Is this a malfunction? 

Solution

That is not a malfunction. Some Analog Input channels of MABX III measure a non-zero voltage if the input is open due to the internal circuitry. 

This behaviour is also observed in other channels on other platforms such as MicroLabBox Analog Input Class 1.

The voltage measured when the input is open depends on the channel type, because each channel type has a different internal structure. 

This has no influence on readings of low-impedance signal sources. 

 

An example is presented in the image that follows, showing measurement results obtained using the Analog In 9 channel type when the input is open.