FAQ 786: How to Measure and Record Data in ControlDesk Using Downsampling (Instead of HostService)
Question
I have a simple Simulink model built and run on a DS1401 target.
I would like to select a raster for recording in ControlDesk 6.3, but I can only select "HostService" which is the sampling time specified in the model.
Is it possible to set and select a different raster in ControlDesk or at build time?
Specifically, I would like to record a raster that is specified as 1ms, but then thinned out to 10ms, 100ms, and so on.
Solution
As a method for performing measurement and recording at integer multiples of the basic sample time, ControlDesk provides the “Down Sampling function”.
Please follow the procedure below.
Setting up downsampling (measurement thinning):
- Open a project in ControlDesk.
- Right-Click "Measurement Configuration" > "Acquisition" > "Platform" > "HostService". Then select “Properties”.
- Downsampling is displayed in “Properties”. (Default setting=1)
In the default setting, measurement and recording are performed at the basic sample time.
- Enter an integer value in the Downsampling field.
(If the basic sample time is 1 ms, enter 10 for 10 ms, 100 for 100 ms, etc.)
*Downsampling settings are also applied during recording.