FAQ 280: Error message "DAQ/STIM list is inconsistent", RCP
Question
A warning message "The mode configuration of a DAQ/STIM list is inconsistent. (failure checking not supported without service" appears in the “DCI-GSI2 Status > Device Message” section of the DCI Configuration Tool.(*1) Is there any way to resolve this issue?
*1
Solution
In the Access Configuration of the ECU Interface Manager, which is used to create EIC files, disabling the "Data Receive Synchronization"[Fig.1] property may stop the warning message. One possible cause of this warning is that the configured Event Channel does not support the "Double Buffer Mechanism," also known as the failure check mechanism. By disabling the Data Receive Configuration, it implies that the Double Buffer Mechanism will not be used, thereby resolving the configuration mismatch.
The “Data Receive Synchronization” property reflects the configuration defined in the A2L file. Therefore, if the section of “XCP_Bypassing” in “IF_DATA dSPACE_XCP” definition is set as shown below in the A2L file[Table 1], it will be treated as disabled in the ECU Interface Manager[Fig.2].
Table 1 Section “IF_DATA dSPACE_XCP” is defined in A2L
/begin IF_DATA dSPACE_XCP 0x00010100 /* AML version 1.1.0 = 0x00010100 */ /begin XCP_Bypassing NOT_SUPPORTED /* enable double buffer mode */ NOT_SUPPORTED /* enable ECU wait mechanism */ NOT_SUPPORTED /* enable failure checking */ NOT_SUPPORTED /* enable failsafe page */ /end XCP_Bypassing /end IF_DATA