FAQ 196: ​VEOS CAN Bus Simulation Error invalid Bus Access Request [] baud rate: 0

Question

When simulating a CAN bus in VEOS, the following error message appears:  
"The following CAN bus connector with a flexible rate operation mode has an invalid Bus Access Request [???????\CAN Cluster 1] baud rate: 0." *1  
As a result, the simulation cannot be executed.

*1

Solution

In VEOS, open the project and select the Bus Access Request. Then, go to “Properties” -> “Settings” and enter the specified data rate in the "Baud rate" and "Data phase baud rate" fields. After entering the values, save the settings and update the SDF.