DS6242具有精确的模拟输出通道,可用于快速控制原型(RCP)以及硬件在环(HIL)测试应用。其10个电隔离模拟输出通道支持电压输出和电流灌入。对于电压输出,您最多可以将三个通道组合使用,以覆盖-60V至+60V的电压范围。
在ECU功能的开发过程中,DS6242能够作为执行器控制的模拟信号发生器。在测试场景中,它生成用于传感器仿真的信号。
Technical Details
|
Parameter |
Specification |
|
|---|---|---|
|
Angular processing units |
Number of units |
6 slaves |
|
Maximum speed |
1,200,000 °/s (200,000 rpm) |
|
|
Communication interface |
IOCNET (up to 2.5 Gbit/s link speed) |
|
|
Provided channel types |
|
|
|
I/O connector |
50-pin Sub-D |
|
|
Typical power consumption |
20 W (typ. 0.834 A, at +24 V, with no output load) 24 W (typ. 1 A, at +24 V, with all outputs in voltage out mode each channel with 20 mA load.) |
|
|
Physical size |
|
|
Analog Out 21 Channel Type
|
Functionality |
Parameter |
Specification1) |
|---|---|---|
|
Analog voltage out |
Output voltage (signal pin to reference pin) |
-20 V ... +20 V |
|
Reference voltage (reference pin to GND) |
-60 V ... +60 V |
|
|
Working voltage range (signal pin to GND) |
-60 V ... +60 V |
|
|
Output current |
-40 mA … +40 mA |
|
|
Resolution |
16 bit |
|
|
Settling time2) |
4 µs (typ.) |
|
|
Update rate |
1 MS/s |
|
|
Gain error |
±0.1% (typ.) |
|
|
Offset error |
±2 mV (typ.) |
|
|
Current sink |
Output current |
-20 μA … -40 mA and 20 μA … 40 mA |
|
|
Reference voltage (reference pin to GND) |
-60 V ... +60 V |
|
|
Working voltage range (signal pin to GND) |
-60 V ... +60 V |
|
|
Analog output voltage |
-2 V … -60 V or 2 V … 60 V3) |
|
|
Output current |
-20 μA … -40 mA or 20 μA … 40 mA3) |
|
|
Resolution |
15 bit |
|
|
Max. frequency |
140 kHz (typ.) |
|
|
Update rate |
1 MS/s |
|
|
Gain error |
±0.1% (typ.) |
|
|
Offset error |
±10 μA (typ.) |
|
Supported function blocks |
|
|
|
Channel multiplication |
Voltage enhancement |
|
|
Current enhancement |
|
|
|
Failure routing unit (FRU) |
No |
|
1) Unless stated otherwise, the specifications are valid only if the dSPACE hardware is correctly connected to the power, switched on, and ready for operation.
2) Full-scale range (FSR) step, value generally depends on output load condition.
3) It depends on the voltage direction whether the current is negative or positive.
4) You cannot use current enhancement and voltage enhancement at the same time.
Trigger In 4 channel type
|
Functionality |
Parameter |
Specification |
|---|---|---|
|
Trigger voltage in |
Input voltage |
0 V ... +60 V |
|
Input threshold voltage |
0 V … +23 V |
|
|
Hysteresis |
600 mV (typ.) |
|
|
Input resistance |
360 kΩ |
|
|
Threshold voltage resolution |
8 bit |
|
|
Supported function blocks |
Trigger In |
|
|
Channel multiplication |
No |
|
|
Failure routing unit (FRU) |
No |
|