RTICAN 2.6.1 Patch 1 for Release 5.2

Introduction
Problems Fixed by This Patch
Limitations
Installation Notes & Download

Introduction

This patch can be installed only after the installation of dSPACE Release 5.2.

Problems Fixed by This Patch

When you update to dSPACE Release 5.2 and reopen your existing model, the RTICAN Controller Setup blocks in the model determine wrong values for the CAN controller frequencies and for the bit timing registers BTR0 and BTR1.
As a result, CAN communication on the related CAN controllers will be corrupt.

The patch fixes the problem described above.

Limitations

The patch fixes the problem described above only if you have not yet opened and saved the Simulink® model after upgrading to dSPACE Release 5.2.

Otherwise, use the workaround described in the Installation Notes file.

Installation Notes & Download

Installation Notes (2.4 KB)
RTICAN261p1.exe (199 KB)

Tags
Date 2007-01-23
Software Type Implementation Software, Bus and Network Software
Product RTI (Real-Time Interface), RTI CAN Blockset
Information Type Patches
Information Category Troubleshooting
dSPACE Release Prior to 2013-A

Drive innovation forward. Always on the pulse of technology development.

Subscribe to our expert knowledge. Learn from our successful project examples. Keep up to date on simulation and validation. Subscribe to/manage dSPACE direct and aerospace & defense now.

Enable form call

At this point, an input form from Click Dimensions is integrated. This enables us to process your newsletter subscription. The form is currently hidden due to your privacy settings for our website.

External input form

By activating the input form, you consent to personal data being transmitted to Click Dimensions within the EU, in the USA, Canada or Australia. More on this in our privacy policy.