I set a trigger on the recorder in ControlDesk and started the measurement with [Start Triggered], but the record does not start even if the trigger condition is satisfied.
As an error message, I saw the following:
An exception has occurred when accessing ClibAccess. DspErrorCode: 1004
The real-time data capture on the following device was too fast for the PC: Platform. Some data might be lost.
Increase the downsampling factor or capture fewer signals to decrease the amount of data. Then restart the capture.
The real-time data capture was stopped. The real-time hardware captured data that was too fast for the PC. Try one of the following solutions:
1. Increase the downsampling factor
2. Capture fewer signals to decrease the amount of data[0.000]