DS2642 FIU & Power Switch Board

HighFlex board for power-switching with Failure Insertion Unit

The DS2642 FIU & Power Switch Board combines two components:

  • Central Failure Insertion Unit (FIU) for simulating failures for the I/O channels of the SCALEXIO HighFlex boards and MultiCompact units
  • Power switches for simulating up to 10 switched potentials, for example, on terminal K15

Technical Details

Parameter Specification
Power switches (Power Switch 1)
  • General
    • 10 channels for the ECU's current supply
    • Voltage 60 V
    • Continuous current 10 A per channel
    • Channel parallelization to increase the measurement range to max. 80 A (RMS)
    • Status LED for overall board status
    • 10 channel-specific LEDs for channel status (power switch open/closed)
  • Current measurement
    • Current measurement on each channel
    • Precision mode
      • Resolution 6.25 µA
      • Sampling time 135 ms
      • Measurement range 0 ... 1.6 A
    • Dynamic mode
      • o Resolution 150 µA
      • Sampling time 262 µs
      • Measurement range 0 A ... 39 A
  • Electronic fuses
    • 10 A RMS ECU (effective value)
    • Software-configurable and software-resettable
Failure Insertion Unit
  • General
    • Voltage ±60 V
    • Fault switch for up to 80 A
    • Continuous current for high-current failrail 80 A
    • Continuous current failrail with low capacitance 1 A
    • Status LED for the FIU component
  • Fault types
    • Broken wire
    • Short circuit to GND or UBat
    • Crossed wire between two channels
    • All faults with optional bouncing
Internal communication interface
  • IOCNET
Physical size
  • 410 x 100 x 41 mm (16.1 x 3.9 x 1.6 in)
  • Requires 2 slots
Voltage supply
  • 24 V
Typical power consumption
  • 19.2 W

This sounds interesting. Get in touch:

Stay up-to-date with our dSPACE direct newsletter service.

With our dSPACE newsletter service, we will keep you informed about current use cases and new solutions and products, as well as trainings and events. Sign up here for a free subscription.

Enable form call

At this point, an input form from Click Dimensions is integrated. This enables us to process your newsletter subscription. The form is currently hidden due to your privacy settings for our website.

External input form

By activating the input form, you consent to personal data being transmitted to Click Dimensions within the EU, in the USA, Canada or Australia. More on this in our privacy policy.