dSPACE SystemDesk 25.1 August 2026 Last-Minute Information ************************************************************************* Copyright 2026 dSPACE SE & Co. KG, Germany Contents: 1. General 2. Improvements and Fixed Problems 2.1 Improvements and Fixed Problems by Previous Patches 3. Limitations 4. Installing the Patch 1. General ************************************************************************* This Patch can only be installed to update an existing SystemDesk 25.1 installation. 2. Improvements and Fixed Problems ************************************************************************* SystemDesk 25.1 Patch 3: Modeling - Fixed an issue where the ECU configuration did not need to be synchronized when changes were made to the "SwCalibrationAccess" property of data types. - Fixed an issue when selecting a container in an inherited ECU module configuration. - Fixed an issue that occurred when importing a module configuration because a reference could not be resolved. - Fixed a rounding issue that caused the validation error R538 to be thrown incorrectly. V-ECU Generation - Updated CAN controller mode handling to allow STOP requests for controllers already in the STOPPED state, ensuring AUTOSAR-compliant behavior. - Added LIN slave support for V-ECU FMUs, enabling communication with external LIN master nodes through header reception, response handling, and LIN interface callbacks. With the existing LIN master support, V-ECU FMUs now provide full LIN communication capabilities in both master and slave operation modes. - New Feature: V-ECU Generation Framework The V-ECU Generation Framework is a new set of command-line tools for generating FMI 3.0 FMUs for LVL3 AUTOSAR MCAL V-ECUs. The framework uses AUTOSAR ARXML files and human-readable configuration files as input for version-controlled workflows. Its lightweight and portable architecture allows seamless integration into CI/CT pipelines and automated build environments. The framework, including initial documentation, is available in the VEcuGenerationFramework subfolder of the SystemDesk installation directory. Additional documentation, examples, and guidance will be provided with the upcoming SystemDesk 26-B Release. For further information, contact support@dspace.com. - Fix the time delay after the reintegration of an ECU because the removal of a workaround was incomplete. - Improved LIN transmission handling by resetting the controller state after completed transmissions and supporting cancellation of ongoing transmissions when a new frame transmission is requested. - Added support for integrating virtual hardware implemented in C code into V-ECU FMUs and connecting it to MCAL I/O interfaces for simulation of hardware-related software components. - Fixed CAN controller mode handling to correctly process requests to set a controller to the STOPPED state when it is already stopped. - MessageSent counter of CAN hwh objects was not decremented for lost or overrun messages - Fixed cold start handling in FlexRay so the node retries startup correctly, listens properly on the bus, and aborts startup when required conditions are not met. - Fixed an issue in the FMI-LS-BUS Ethernet driver (in AUTOSAR 4.1 mode) where TX buffers were not properly released after transmission, potentially leading to blocked transmissions. - Fixed an infinite loop when a transmission occurs at time 0. - Updated Ethernet internal error handling to correctly support configurations without a DET module. - Adds the declaration of Eth_FmiIf__TxClk_SetInterval function for applicable EthernetController. - Added implementation for GetChannelStatus AUTOSAR API function in the FlexRay module. - A format error operation is sent, if a bus operation is received that does not match the expected format. - Fixed the microtick conversion to use correct nanosecond values and made the validation rule consistent. - The behavior of the FR driver has been aligned with the latest version of the FMI Layered Standard for Network Communication. As a result, the last-is-best reception window for FlexRay messages now spans a full communication cycle (see fmi-ls-bus Issue #363 for details). - Handled the FlexRay configuration operation so received parameters are validated for compatibility and errors are reported if mismatched. - Added implementation for GetSyncFrame AUTOSAR API function in the FlexRay module. - Updated LIN and Ethernet code generation to use default clock timing settings when the clock timing container is not configured, allowing generation to continue. - GetNumOfStartupFrames AUTOSAR API is now implemented in the FlexRay module. - The value of the FrIfMainFunctionPeriod parameter in the FlexRay interface is not lost when the update script is used. - PDU mapping buffer was checked after initiating Can message transmit, resulting in possible problems if the buffer was full. - Added the "Update LIN Configuration" build action for LS-BUS LIN module in model-based V-ECUs, enabling automatic LIN configuration updates from the module configuration. - Added generation of AUTOSAR IOC functions for the FMU OS, enabling inter-OS-application communication in accordance with the AUTOSAR specification. Security - This patch contains various security fixes for dSPACE and third-party components. For corresponding third-party updates, refer to the SystemDesk_25.1_OSSAcknowledgements.txt in the legal notices file. 2.1 Improvements and Fixed Problems by Previous Patches ************************************************************************* SystemDesk 25.1 Patch 2: Modeling - Fixed an issue where an InvalidValue of an ApplicationPrimitiveDataType was resolved incorrectly if the CompuMethod was a type of any TEXTABLE. - Fixed an issue where a ServiceSwComponent was incorrectly removed from the EcuFlatView during synchronization when its ServiceSwComponentType was not located under the EcuConfiguration node. V-ECU Generation - The default value for the BusNotifications parameter has been updated to match the standard. - The EcuMFixedUserConfig symbolic names are generated in a deterministic alphabetical order. - Fixed an issue where RTE interventions could cause an exception when more than 65535 intervention IDs were used. - Increased RxOperationBufferElementSize to 1536. - The basic module structure for the LS-BUS LIN driver is supported. - Fixed an issue where BSW module scripts for certain modules would fail when the VECU_GENERATION_PYTHON_EXECUTABLE environment variable was set. - Fixed Sfc, Cdd, and PduR EPD files to support 3rd-party EcuC module configuration. - Correct target configuration file is now used for A2L update. - Fixed an issue where the Platform_Types.h file was not AUTOSAR-compliant. - Fixed RTE read intervention points for degradated delegation ports. - A warning message is given instead of an error message if the generated A2L element name exceeds 128 Char. - Adjusted the Sab reset message to a more meaningful message when successive reset signals are detected. - Fixed OsCounterMaxAllowedValue with MaxAllowedValue as uint32. - Fixed an issue that set the EXECUTION-CONTEXT of an BswModuleEntry for a PROVIDED-CLIENT-SERVER-ENTRY to UNSPECIFIED instead of TASK. - Validation of the XCP module in the FMU is now executed before XCP code generation. - Adapted CAN module to support AR4.3.1 CanIfARVersion. - The watchdog is now re-armed on each valid call to Wdg_SetTriggerCondition(). Security - This patch contains various security fixes for dSPACE and third-party components. For corresponding third-party updates, refer to the SystemDesk_25.1_OSSAcknowledgements.txt in the legal notices file. SystemDesk 25.1 Patch 1: Modeling - Improved rounding of scaled limit value for the A2L export. V-ECU Generation - This patch for SystemDesk 2025-B contains a preview version of the Ethernet Driver for FMI 3.0 with the Layered Standard for Network Communication 1.2.0-alpha.2 for use with dSPACE VEOS 2025-B or other simulators compliant with this pre-release of the layered standard. The preview version of the driver implements AUTOSAR 4.1/4.2/4.3 and supports basic operations such as transmission, reception and mode management. Limitations are that the following features are not yet supported: - Priorization/Filtering with multiple transmission/reception queues (All queues are treated equal) - Transmission/Reception statistics and counters - Time synchronization - Improved RTE generation performance for software components with a large number of parameter accesses. - Fixed the generation of invalid A2L ECU_ADDRESS values for data elements with an "SCALE_LINEAR_AND_TEXTTABLE" compu method. - Reverted the change of A2L variable naming for data elements using compu methods with multiple compu scales (e.g., Var_1, Var_2, ... instead of Var, Var_1, ...). - Fixed an error in the array layout of reversed application data types during A2L import. - Fixed a problem where the Update COM Configuration incorrectly reported an error for IDTs of the TYPE_REFERENCE category. 3. Limitations ************************************************************************* SystemDesk projects saved by this patch cannot be opened with previous versions of SystemDesk. 4. Installing the Patch ************************************************************************* To install the patch, you must be logged on with administrator rights and all hotfixes of the current version have to be removed. Close your SystemDesk application and run the executable file. The setup automatically locates and patches the SystemDesk installation. After this patch is installed, it is displayed in the splash screen, about box, and message browser. *************************************************************************