======================================= Contents of ControlDesk 2024-B (24.2p2) ======================================= Contents of this file - General - Changes in ControlDesk 2024-B (24.2p2) - Changes in ControlDesk 2024-B (24.2p1) ------- General ------- Version of this information file: 2.0.1 ControlDesk 2024-B (24.2p2) is a patch for ControlDesk 2024-B. It includes bug fixes and improvements for ControlDesk 2024-B from January 2026 to June 2026. This patch is cumulative and includes all bug fixes and improvements from all previously released patches for ControlDesk 2024-B. The patch can be installed on an existing installation of ControlDesk 2024-B. It can be uninstalled if wanted. For uninstalling patches and hot fixes refer to FAQ 186: http://www.dspace.com/faq?186 ------------------------------------------------------------------------------ Changes in ControlDesk 2024-B (24.2p2) compared to ControlDesk 2024-B (24.2p1) ------------------------------------------------------------------------------ Bus Navigator: -------------- - Fix: ControlDesk Ethernet monitor sometimes shows unexpected multi-second jumps in timestamps. (1367768) - Improvement: The performance when loading .expswcfg files has been improved. (1452421) - Fix: The tool could crash when saving an Ethernet monitoring file using a SCALEXIO interface that could not be accessed when the monitor was stopped. (1501093) - Fix: The tool could crash by loading Ethernet ARXML files where TP Configurations is Generic-TP. (1552039) - Fix: When loading an .expSwCfg file, the name for the file is derived by splitting the trace file name at the first "." and only the first segment is taken. This logic failed if the trace filename contained multiple dots. (1560584) Data Set Manager: ----------------- - Fix: When creating the application image file outside the experiment for MC/MP applications, the application image only contained the part of the last "Create Application Image" command. (1569581) ECU Diagnostic: --------------- - Fix: Due to security vulnerabilities, the D3 Server versions have been updated. (1649147) Measurement Management: ----------------------- - Fix: The tool could crash when using Switch Data Source for instrumented variables with non-numeric scalings. (1582902) Platforms / Devices: -------------------- - Fix: The tool could freeze if a USB to Ethernet adapter connecting the platform to the PC was removed and quickly reconnected during a running measurement. (1542535) Security Vulnerabilities: ------------------------- - Fix: Due to security vulnerabilities, the D3Server versions have been updated. (1574991) - Fix: Due to security vulnerabilities, the TMW libraries versions have been updated. (1627339) Variables Management: --------------------- - Fix: Variable mappings could be deactivated while the tool is online or measuring, which means that the variables could then no longer be resolved. (1572379) - Fix: The search window in the "Variables" tab overlapped the scrollbar of the variables list. (1603909) - Improvement: The handling of XIL mapping files from build results in ControlDesk experiments was improved. (1607522) - Fix: Adding variables to the Measurement Signal List via .SPPath was not possible via toolautomation, if sub-application and sub-model had the same name. (1614619) - Fix: The functionality of the ECU address extension in A2L for standard axes was not supported. (1643006) Visualization: -------------- - Fix: The line styles "Staircase" and "Area Staircase" of a plotter instrument were not functional in a newly created plotter. (1525921) - Fix: The option in the time plotter to deactivate one variable erroneously deactivated all variables. (1542069) - Fix: A maximized split screen with two layouts led to a minimized layout as soon as you clicked somewhere else (e.g. in another layout) and again in one of the two layouts in split screen mode. (1542507) - Fix: The tool could crash when importing several layouts in a loop using toolautomation that contained plotter instruments with a visible toolbar. (1551917) - Fix: The access to OpenStreeMaps tiles in the map instrument (Browser Examples) was fixed. (1610292) - Fix: An instrument could not be connected via SPPath if sub-application and sub-model had the same name. (1627166) ---------------------------------------------------------------------------- Changes in ControlDesk 2024-B (24.2p1) compared to ControlDesk 2024-B (24.2) ---------------------------------------------------------------------------- Automation: ----------- - Fix: The tool could crash if the license was unavailable while the tool was quitting via toolautomation while not saving the experiment - "Application.Quit(False)". (1328561) - Fix: The "ContainsByPath" method did not work correctly if the trc file had the same name as the (sub-)platform in the experiment. (1508227) Bus Navigator: -------------- - Fix: When expanding a PDU with a signal longer than 255bit in the Monitoring View, the tool crashed. (1188918) - Fix: When a text representation was used for the TX signal in the generated layout, the coded value of the signal was used for transmission instead of the physical one. (1226376) - Fix: The import of variable descriptions (.arxml) containing Fire & Forget methods was not possible in some cases for Ethernet Monitoring Device. (1315086) - Fix: The source information for container PDUs was not shown on the generated instrument. (1341173) - Fix: If "Generate Array Representation" was enabled, the support for Parameters/Arguments of type "Array" was missing. (1382114) - Fix: Folders becoming unneeded during replacing of a variable description were not removed. (1389468) - Fix: Some source cells were empty in generated PDU layouts. (1437912) - Fix: Resolved duplicate display of variables for Value Access and Inspection Ethernet Parameters and Arguments on Bus Navigator layouts. (1514977) - Fix: The automatic creation of instruments on a Layout via the context menu for Ethernet Services, Events, Methods, and PDUs originating from the Ethernet Configuration Package was introduced. (1534982) Data Set Manager: ----------------- - Fix: If the .RTA and .SDF filenames differed from the .MAP and .TRC filenames, it was not possible to create an application image file. (1228723) - Improvement: ASAM CDF 2.1 files (.CDFX files) generated by MATLAB could not be imported. (1418337) - Fix: Error message were generated when using "Create Data Set from Open Layout" if Tunable Parameter were present on the layout. (1430534) Demos: ------ - Fix: The Relay Maintenance Demo from the installation was not functional and is replaced. Please import the demo project again. (1259894) ECU Diagnostic: --------------- - Fix: Added disconnect convenience functionality of the diagnostic device when unloading a VEOS or SCALEXIO application. (46229) - Improvement: The option to deactivate the transfer of optional bytes has been implemented. (1178014) - Improvement: Functional Addressing was not working for the Base Variant Logical Link. (1184595) - Improvement: The support of Send-Only service of ODX was implemented. (1208735) - Fix: The support of sending DoIP version 3 activation header requests was implemented. (1211826) EES Port: --------- - Fix: If the EES port was deactivated and then reconfigured, it then issued an error message. (1367520) Global: ------- - Fix: In certain environments, the tool could hang on startup, especially during installation. (1290843) - Fix: In some cases a maximized layout or Python document was minimized as soon as you clicked anywhere else, e.g. a different layout. (1468869) - Improvement: Due to security vulnerabilities, we have updated the JAVA Open JDK to version 17.0.17+10. (1511424) Measurement Management: ----------------------- - Fix: It was not possible to export a measurement data file as .MAT with special characters in the name or content. Limitation: File path and name may only contain special characters matching the codepage of the current PC. (1188445) - Fix: With MP/MC systems, the signals that were already present in the new raster were deleted when switching to another raster with a multiple selection. (1233663) - Fix: The platform assignment was incorrectly resolved when dragging and dropping variables to the measurement signal list if several sub variable descriptions contained the same variable identifiers. (1236065) - Fix: When recording signals with a rational function scaling the formula was inverted. (1313565) - Fix: No error messages were displayed when loading MF4 files with invalid meta data failed. (1322409) - Fix: It was not possible to remove certain curves from a MF4 file. (1330300) - Fix: The option UsePlatformDefaultRasterForParametersEnabled was not functional for MC/MP platforms. (1387313) - Fix: Variables from an MC/MP application were not restored when reactivating a deactvated recorder. (1390291) - Fix: Reloading variable descriptions needed too much time if a large amount of variables were in the measurement configuration. (1395556) - Fix: When installing ControlDesk Release 2024-B or 2025-A, the Measurement Data API of a ControlDesk release prior to 2024-B became unusable. (1424736) Platforms / Devices: -------------------- - Fix: Very long messages from SMART type platforms (e.g. SCALEXIO) lead to a crash of the tool. (877513) - Improvement: The tool could not communicate with an IP V6 ECU in an IP V6 network (also peer to peer communication was impossible). (1021767) - Fix: The tool froze if no response (RES) to an XCP command was sent by the XCP service of the ECU. (1310249) - Fix: Configuring a XIL API MAport did not work for RTMaps applications. (1345040) - Fix: The tool could crash if the XLI API MAPort platform could not be created when starting the tool. (1356016) - Fix: The capture was not restarted after performing start/stop capture via toolautomation. (1376708) - Improvement: The evaluation of XCP responses for ADD_xy checksums was improved. (1483532) - Fix: In some cases the termination of a diagnostic flash-job did not work. (1499927) Project / Experiment: --------------------- - Improvement: The error message when exceeding the Windows path length limitation of the CDP file path during project conversion has been improved. (1262536) Signal Editor: -------------- - Fix: The tool could crash, if a signal name was changed and directly afterwards the view set was changed. (1166103) - Fix: The tool could crash when closing the active project if a signal generator has been downloaded and the hardware is powered off. (1370461) Variables Management: --------------------- - Fix: The tool could crash when copying or moving an instrument connected to an array variable. (1233760) - Improvement: When importing very large A2L files, an internal "out of memory" exception could occur. (1260322) - Fix: The size in bytes of axis and function values was not calculated correctly when using STATIC_RECORD_LAYOUT in an A2L file. (1267115) - Fix: The tool did not support the MATRIX_DIM keyword if it was used in a STRUCTURE_COMPONENT. (1276755) - Fix: The StatusString scaling from TRC variable descriptions did not work. (1312905) - Fix: Memory was not freed after reloading a variable desciption if at least one connected instrument on a layout was existing. (1315036) - Fix: The use of infinity values in XIL API mapping files could cause the tool to crash. (1326155) - Fix: A Project/Experiment could be corrupted after reloading a variable description while access problems in the experiment file structure existed. (1388547) - Improvement: Improved performance of reloading a variable description when there are many variables in the measurement configuration. (1395498) - Fix: In some cases the logged module name was wrong. (1468005) - Fix: Adding a variable description without BuildResultMappings after adding a variable description with BuildResultMappings did not clear the mappings browser. (1490440) Visualization: -------------- - Fix: When double-clicking in a grid cell of a table editor instrument with a z-axis and manually connected x- and y-axis variables, the tool crashed. (1247264) - Fix: Bit numbering in the bitfield in instruments was not shown if the font was not available. (1313948) - Fix: In some cases the tool could crash when using the command "Create Layout Copy". (1503604) - Fix: In some cases, the tool could crash when using measured values for a manually created signal. (1505991) - Fix: The tool could crash if the cell type of a non-visible HierarchyArray was changed. (1517110) =============== End of Contents ===============