dSPACE Model Compare 2023-B P1325210 (MOC23.1p2) Mar 2025 Last-Minute Information ===================================================== Copyright (c) 2025 dSPACE GmbH, Germany Contents: 1. General 2. Content of This Patch 3. Limitations and Workaround 4. Installing the Patch ===================================================== 1. General ------------------------------------------------------------------------------ This patch can be installed only after the installation of Model Compare 2023-B (23.1) from dSPACE Release 2023-B or 2024-A. 2. Content of This Patch ------------------------------------------------------------------------------ This patch fixes the following issues: - Incompatibility with dSPACE Installation Manager of Release 2025-A repaired: If you have installed parts of Release 2025-A or the dSPACE Installation Manager 25.1 with a separate setup, Model Compare 2023-B can no longer be configured concerning the dSPACE MATLAB Connection. Install this hotfix to ensure compatibility again. Additionally, fixes of the following issues already fixed with Patch 1 and Hotfix 1 and 2 are also included: - Some Simulink subsystems containing a lot of lines were slowing down the comparison time in the UI, i.e., the time needed to calculate the hierarchy correspondence. The Windows application did not react for a long time when the comparison session was started. - Signal lines were not always reconnected after Comfort Copy started from CLI. - PDF report of Accelerated Comparison was enhanced. - Filters improved for use with Accelerated Comparison. - Read-only support for use with Git was incorrect. New CLI options '-LeftReadOnly on' and '-RightReadOnly on' are introduced. - Session load behavior was inconsistent if using Accelerated Comparison. - Indication of probably wrong or missing libraries was incorrect. - A stable interface for automerge was missing. 'ModelCompare.GitAutoMerge.cmd' can now be used as stable CLI. - A stable interface for report generation was missing. 'ModelCompare.DiffReport.cmd' can now be used as stable CLI. - Dump library 'off' was not evaluated properly. - Even if no hook function was provided, time-consuming Simulink functions for hook determination were called. - Model Compare crashed after redump with "Specified Method is Not Supported" if the feature "Subsystem dump" was used. - Report did not create images if models with same name from different folders were compared and "Using running session" was configured. - Report did not create any images when Accelerated Model Comparison (AMC) warnings used. - Report generation failed if a Simulink annotation was present in the Simulink library block during image creation. - Comfort Copy did not merge lines properly if block with same name was present in a different location. - Resolving conflicts from Git extension might have led to "Operation failed" issue. - Comfort Copy feature might have failed during line merge when AMC was used. - Simulink Truth Table was not displayed in Navigator tree and not merged during a Comfort Copy. - The warning "We found unexpected differences" (due to incorrectly loaded Simulink libraries) was sometimes issued unneccesarily. It is recommended that this patch for Model Compare 2023-B should be installed by all users who have problems as described above and by all users before or directly after installing dSPACE Release 2025-A or later. The same is true when installing dSPACE Installation Manager 25.1 or later. 3. Limitations and Workaround ------------------------------------------------------------------------------ The patch fixes the problems of Model Compare 2023-B as described above. There is no limitation, except that you must have Model Compare 2023-B installed from dSPACE Release 2023-B or 2024-A. If you want to uninstall the patch once you have installed it, you have to uninstall Model Compare 23.1 and reinstall it. 4. Installing the Patch ------------------------------------------------------------------------------ To install the patch, you must be logged on with administrator rights. Ensure that Model Compare 2023-B is installed. To install, simply run the executable. The setup will automatically locate and patch the Model Compare 2023-B installation. The splash screen and the About box of Model Compare will indicate if the patch was successfully installed. Remember to install this patch again if you reinstall Model Compare 2023-B or install Model Compare on an additional computer. If you have any difficulty with this installation, please contact dSPACE Support: https://www.dspace.com/go/support ------------------------------------------------------------------------------ End of File